Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Ultrason Imaging ; 46(2): 130-134, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38318708

RESUMEN

Subharmonic aided pressure estimation (SHAPE) is a technique that utilizes subharmonic signals from microbubble contrast agents for pressure estimation. Validation of the SHAPE technique relies on synchronous measurements of in vivo pressures using contrast microbubbles and a pressure catheter (reference standard). For the guidance and placement of pressure catheter in vivo, iodinated contrast is used with fluoroscopy. Therefore, during data acquisition for validation studies of the SHAPE technique, both contrast microbubbles and iodinated contrast are present simultaneously within the vasculature. This study aims to elucidate the effects of iodinated contrast (Visipaque, GE HealthCare) on subharmonic signal amplitude from contrast microbubbles (Definity, Lantheus Medical Imaging, Inc.). In an acrylic water tank, 0.06 mL of Definity and varied amounts of Visipaque (0.14, 0.43, 0.85, and 1.70 mL) were added to 425 mL of deionized water. Ultrasound scanning was performed with a SonixTablet scanner (BK Medical Systems) using optimized parameters for SHAPE with Definity (ftransmit/receive = 3.0/1.5 MHz; chirp down pulse). Subharmonic data was acquired and analyzed at 9 different incident acoustic outputs (n = 3). Results showed an increase in subharmonic signal amplitude from Definity microbubbles in the presence of 0.14 mL Visipaque by 2.8 ± 1.3 dB (p < .001), no change with 0.85 mL Visipaque (0.7 ± 1.2 dB; p = .09) and a decrease in subharmonic amplitude in the presence of 1.70 mL Visipaque by 1.9 ± 0.7 dB (p < .001). While statistically significant effect on subharmonic signal amplitude of Definity microbubbles was noted due to the mixture, the magnitude of the effect was minimal (~2.8 dB) and unlikely to impact in vivo SHAPE measurements.


Asunto(s)
Medios de Contraste , Fluorocarburos , Ácidos Triyodobenzoicos , Agua , Ultrasonografía/métodos
2.
Radiol Cardiothorac Imaging ; 6(1): e230153, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38358329

RESUMEN

Purpose To investigate if the right ventricular (RV) systolic and left ventricular (LV) diastolic pressures can be obtained noninvasively using the subharmonic-aided pressure estimation (SHAPE) technique with Sonazoid microbubbles. Materials and Methods Individuals scheduled for a left and/or right heart catheterization were prospectively enrolled in this institutional review board-approved clinical trial from 2017 to 2020. A standard-of-care catheterization procedure was performed by advancing fluid-filled pressure catheters into the LV and aorta (n = 25) or RV (n = 22), and solid-state high-fidelity pressure catheters into the LV and aorta in a subset of participants (n = 18). Study participants received an infusion of Sonazoid microbubbles (GE HealthCare), and SHAPE data were acquired using a validated interface developed on a SonixTablet (BK Medical) US scanner, synchronously with the pressure catheter data. A conversion factor, derived using cuff-based pressure measurements with a SphygmoCor XCEL PWA (ATCOR) and subharmonic signal from the aorta, was used to convert the subharmonic signal into pressure values. Errors between the pressure measurements obtained using the SHAPE technique and pressure catheter were compared. Results The mean errors in pressure measurements obtained with the SHAPE technique relative to those of the fluid-filled pressure catheter were 1.6 mm Hg ± 1.5 [SD] (P = .85), 8.4 mm Hg ± 6.2 (P = .04), and 7.4 mm Hg ± 5.7 (P = .09) for RV systolic, LV minimum diastolic, and LV end-diastolic pressures, respectively. Relative to the measurements with the solid-state high-fidelity pressure catheter, the mean errors in LV minimum diastolic and LV end-diastolic pressures were 7.2 mm Hg ± 4.5 and 6.8 mm Hg ± 3.3 (P ≥ .44), respectively. Conclusion These results indicate that SHAPE with Sonazoid may have the potential to provide clinically relevant RV systolic and LV diastolic pressures. Keywords: Ultrasound-Contrast, Cardiac, Aorta, Left Ventricle, Right Ventricle ClinicalTrials.gov registration no.: NCT03245255 © RSNA, 2024.


Asunto(s)
Compuestos Férricos , Hierro , Microburbujas , Óxidos , Humanos , Corazón , Ventrículos Cardíacos
3.
Eur J Radiol Open ; 11: 100538, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38028186

RESUMEN

Purpose: To investigate if clinical non-contrast chest CT studies obtained with PCD CT using much lower radiation exposure can achieve the same image quality as with the currently established EID protocol. Materials/methods: A total of seventy-one patients were identified who had a non-contrast chest computed tomography (CT) done on PCD CT and EID CT scanners within a 4-month interval. Five fellowship trained chest radiologists, blinded to the scanner details were asked to review the cases side-by-side and record their preference for images from either the photon-counting-detector (PCD) CT or the energy-integrating detector (EID) CT scanner. Results: The median CTDIvol for PCD-CT system was 4.710 mGy and EID system was 7.80 mGy (p < 0.001). The median DLP with the PCD-CT was 182.0 mGy.cm and EID system was 262.60 mGy.cm (p < 0.001). The contrast to noise ratio (CNR) was superior on the PCD-CT system 59.2 compared to the EID-CT 53.3; (p < 0.001). Kappa-statistic showed that there was poor agreement between the readers over the image quality from the PCD and EID scanners (κ = 0.19; 95 % CI: 0.12 - 0.27; p < 0.001). Chi-square analysis revealed that 3 out of 5 readers showed a significant preference for images from the PCDCT (p ≤ 0.012). There was no significant difference in the preferences of two readers between EID-CT and PCD-CT images. Conclusion: The first clinical PCD-CT system allows a significant reduction in radiation exposure while maintaining image quality and image noise using a standardized non-contrast chest CT protocol.

4.
J Clin Transl Hepatol ; 11(3): 534-539, 2023 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-36969887

RESUMEN

Background and Aims: Distinguishing alcoholic steatohepatitis (ASH) and nonalcoholic steatohepatitis (NASH) with biopsy alone is often difficult without a reliable clinical context. A novel finding on liver imaging, perivascular branching heterogeneity, has shown promise in distinguishing between these chronic liver diseases. Our study investigated the role of this finding on imaging to differentiate between ASH and NASH. The aim of this study was to determine the utility and reproducibility of this novel radiographic marker to help distinguish ASH from NASH. Methods: This was a retrospective cohort study conducted between 2016 and 2020 in patients with both liver biopsy-confirmed steatohepatitis/chronic hepatitis and abdominal magnetic resonance imaging within 13 months of each other. Two radiologists, blinded to patient clinical history and diagnosis, categorized the appearance of the liver as: 1- homogeneity, 2- mild heterogeneity, 3- moderate heterogeneity, 4- possible perivascular branching, 5- definite perivascular branching. Results: Of the 90 patients in the study, 60 were identified as NASH and 30 as ASH. The area under the curve (AUC) for both reader 1 and 2 when using the 5-point scale was 0.69 (CI: 0.56-0.82, p=0.006) and 0.72 (CI: 0.60-0.85, p=0.001), respectively. The positive predictive value (PPV) for identification of ASH when scoring 5 was 64.7% and 66.7% for reader 1 and 2, respectively. Interclass correlation coefficient was 0.74 in patients with ASH, indicating moderate reliability among both readers. Conclusions: Identification of this perivascular branching pattern on imaging is a promising novel diagnostic marker that can be used with other methods to help distinguish between ASH and NASH.

5.
JACC Cardiovasc Imaging ; 16(2): 224-235, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36648035

RESUMEN

BACKGROUND: Noninvasive and accurate assessment of intracardiac pressures has remained an elusive goal of noninvasive cardiac imaging. OBJECTIVES: The purpose of this study was to investigate if errors in intracardiac pressures obtained noninvasively using contrast microbubbles and the subharmonic-aided pressure estimation (SHAPE) technique are <5 mm Hg. METHODS: In a nonrandomized institutional review board-approved clinical trial (NCT03243942), patients scheduled for a left-sided and/or right-sided heart catheterization procedure and providing written informed consent were included. A standard-of-care catheterization procedure was performed advancing clinically used pressure catheters into the left and/or right ventricles and/or the aorta. After pressure catheter placement, patients received an infusion of Definity microbubbles (n = 56; 2 vials diluted in 50 mL of saline; infusion rate: 4-10 mL/min) (Lantheus Medical Imaging). Then SHAPE data was acquired using a validated interface developed on a SonixTablet scanner (BK Medical Systems) synchronously with the pressure catheter data. A conversion factor (mm Hg/dB) was derived from SHAPE data and measurements with a SphygmoCor XCEL PWA device (ATCOR Medical) and was combined with SHAPE data from the left and/or the right ventricles to obtain clinically relevant systolic and diastolic ventricular pressures. RESULTS: The mean value of absolute errors for left ventricular minimum and end diastolic pressures were 2.9 ± 2.0 and 1.7 ± 1.2 mm Hg (n = 26), respectively, and for right ventricular systolic pressures was 2.2 ± 1.5 mm Hg (n = 11). Two adverse events occurred during Definity infusion; both were resolved. CONCLUSIONS: These results indicate that the SHAPE technique with Definity microbubbles is encouragingly efficacious for obtaining intracardiac pressures noninvasively and accurately. (Noninvasive, Subharmonic Intra-Cardiac Pressure Measurement; NCT03243942).


Asunto(s)
Medios de Contraste , Microburbujas , Humanos , Ultrasonografía/métodos , Valor Predictivo de las Pruebas , Cateterismo Cardíaco/efectos adversos
6.
Curr Probl Diagn Radiol ; 52(3): 180-186, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36470698

RESUMEN

Detection of pulmonary nodules on chest x-rays is an important task for radiologists. Previous studies have shown improved detection rates using gray-scale inversion. The purpose of our study was to compare the efficacy of gray-scale inversion in improving the detection of pulmonary nodules on chest x-rays for radiologists and machine learning models (ML). We created a mixed dataset consisting of 60, 2-view (posteroanterior view - PA and lateral view) chest x-rays with computed tomography confirmed nodule(s) and 62 normal chest x-rays. Twenty percent of the cases were separated for a testing dataset (24 total images). Data augmentation through mirroring and transfer learning was used for the remaining cases (784 total images) for supervised training of 4 ML models (grayscale PA, grayscale lateral, gray-scale inversion PA, and gray-scale inversion lateral) on Google's cloud-based AutoML platform. Three cardiothoracic radiologists analyzed the complete 2-view dataset (n=120) and, for comparison to the ML, the single-view testing subsets (12 images each). Gray-scale inversion (area under the curve (AUC) 0.80, 95% confidence interval (CI) 0.75-0.85) did not improve diagnostic performance for radiologists compared to grayscale (AUC 0.84, 95% CI 0.79-0.88). Gray-scale inversion also did not improve diagnostic performance for the ML. The ML did demonstrate higher sensitivity and negative predictive value for grayscale PA (72.7% and 75.0%), grayscale lateral (63.6% and 66.6%), and gray-scale inversion lateral views (72.7% and 76.9%), comparing favorably to the radiologists (63.9% and 72.3%, 27.8% and 58.3%, 19.5% and 50.5% respectively). In the limited testing dataset, the ML did demonstrate higher sensitivity and negative predictive value for grayscale PA (72.7% and 75.0%), grayscale lateral (63.6% and 66.6%), and gray-scale inversion lateral views (72.7% and 76.9%), comparing favorably to the radiologists (63.9% and 72.3%, 27.8% and 58.3%, 19.5% and 50.5%, respectively). Further investigation of other post-processing algorithms to improve diagnostic performance of ML is warranted.


Asunto(s)
Nódulos Pulmonares Múltiples , Radiografía Torácica , Humanos , Rayos X , Radiografía Torácica/métodos , Estudios Retrospectivos , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Redes Neurales de la Computación , Radiólogos
7.
J Appl Clin Med Phys ; 23(7): e13664, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35699199

RESUMEN

There is no current authoritative accounting of the number of clinical imaging physicists practicing in the United States. Information about the workforce is needed to inform future efforts to secure training pathways and opportunities. In this study, the AAPM Diagnostic Demand and Supply Projection Working Group collected lists of medical physicists from several state registration and licensure programs and the Conference of Radiation Control Program Directors (CRCPD) registry. By cross-referencing individuals among these lists, we were able to estimate the current imaging physics workforce in the United States by extrapolating based on population. The imaging physics workforce in the United States in 2019 consisted of approximately 1794 physicists supporting diagnostic X-ray (1073 board-certified) and 934 physicists supporting nuclear medicine (460 board-certified), with a number of individuals practicing in both subfields. There were an estimated 235 physicists supporting nuclear medicine exclusively (150 board-certified). The estimated total workforce, accounting for overlap, was 2029 medical physicists. These estimates are in approximate agreement with other published studies of segments of the workforce.


Asunto(s)
Oncología por Radiación , Diagnóstico por Imagen , Física Sanitaria/educación , Humanos , Física , Oncología por Radiación/educación , Radiografía , Estados Unidos , Recursos Humanos
9.
Am J Hypertens ; 35(5): 397-406, 2022 05 10.
Artículo en Inglés | MEDLINE | ID: mdl-35079778

RESUMEN

BACKGROUND: This study compared aortic pressures estimated using a SphygmoCor XCEL PWA device (ATCOR, Naperville, IL) noninvasively with aortic pressures obtained using pressure catheters during catheterization procedures and analyzed the impact of a linear-fit function on the estimated pressure values. METHODS: One hundred and thirty-six patients scheduled for cardiac catheterization procedure were enrolled in IRB approved studies. Catheterization procedures were performed according to standard-of-care to acquire aortic pressure measurements. Immediately after the catheterization procedure with the pressure catheters removed, while the patients were still in the catheterization laboratory, central aortic pressures were estimated with the SphygmoCor device (using its inbuilt transfer function). The error between measured and estimated aortic pressures was evaluated using Bland-Altman analysis (n = 93). A linear-fit was performed between the measured and estimated pressures, and using the linear equation the error measurements were repeated. A bootstrap analysis was performed to test the generalizability of the linear-fit function. In a subset of cases (n = 13), central aortic pressure values were also obtained using solid-state high-fidelity catheters (Millar, Houston, TX), and the error measurements were repeated. RESULTS: The magnitude of errors between the measured and estimated aortic pressures (mean errors >6.4 mm Hg; mean errors >8.0 mm Hg in the subset) were reduced to less than 1 mm Hg after using the linear-fit function derived in this study. CONCLUSIONS: For the population examined in this study, the SphygmoCor data must be used with the linear-fit function to obtain aortic pressures that are comparable to the measurements obtained using pressure catheters. CLINICAL TRIALS REGISTRATION: Trial Numbers NCT03243942 and NCT03245255.


Asunto(s)
Presión Arterial , Determinación de la Presión Sanguínea , Presión Sanguínea , Determinación de la Presión Sanguínea/métodos , Cateterismo Cardíaco , Catéteres , Humanos
10.
J Ultrasound Med ; 41(7): 1781-1789, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34724241

RESUMEN

OBJECTIVES: Subharmonic aided pressure estimation (SHAPE) has been shown effective for noninvasively measuring hydrostatic fluid pressures in a variety of clinical applications. The objective of this study was to explore potential improvements in SHAPE sensitivity using monodisperse microbubbles. METHODS: Populations of monodisperse microbubbles were created using a commercially available microfluidics device (Solstice Pharmaceuticals). Size distributions were assessed using a Coulter Counter and stability of the distribution following fabrication was evaluated over 24 hours. Attenuation of the microbubble populations from 1 to 10 MHz was then quantified using single element transducers to identify each formulation's resonance frequency. Frequency spectra over increasing driving amplitudes were investigated to determine the nonlinear phases of subharmonic signal generation. SHAPE sensitivity was evaluated in a hydrostatic pressure-controlled water bath using a Logiq E10 scanner (GE Healthcare). RESULTS: Monodisperse lipid microbubble suspensions ranging from 2.4 to 5.3 µm in diameter were successfully created and they showed no discernable change in size distribution over 24 hours following activation. Calculated resonance frequencies ranged from 2.1 to 6.3 MHz and showed excellent correlation with microbubble diameter (R2 > 0.99). When investigating microbubble frequency response, subharmonic signal occurrence was shown to begin at 150 kPa peak negative pressure, grow up to 225 kPa, and saturate at approximately 250 kPa. Using the Logiq E10, monodisperse bubbles demonstrated a SHAPE sensitivity of -0.17 dB/mmHg, which was nearly twice the sensitivity of the commercial polydisperse microbubble currently being used in clinical trials. CONCLUSIONS: Monodisperse microbubbles have the potential to greatly improve the sensitivity of SHAPE for the noninvasive measurement of hydrostatic pressures.


Asunto(s)
Medios de Contraste , Microburbujas , Determinación de la Presión Sanguínea , Humanos , Transductores , Ultrasonografía
11.
Skeletal Radiol ; 50(7): 1399-1409, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33404668

RESUMEN

OBJECTIVE: To evaluate adults with history of Osgood Schlatter disease (OSD) for imaging features of lateral patellofemoral maltracking. METHODS: In a span of four years, 10,181 unique non-contrast knee MRIs were performed on patients aged 20-50. Patients with acute trauma, prior surgery, and synovial pathologies were excluded. 171 exams had imaging findings of OSD, and an age-matched control group of 342 patients without OSD was randomly selected. Two radiologists retrospectively reviewed MRIs for features of lateral patellofemoral maltracking. Maltracking was defined as edema in superolateral Hoffa's fat or a tibial tuberosity-trochlear groove (TT-TG) distance ≥20 mm with either patellar tilt/translation. Binomial logistic regression identified predictors of maltracking in OSD. Optimal TT-TG distance to indicate maltracking was determined by receiver operating characteristic curve. RESULTS: 59% (101/171) of the knees with OSD showed findings of maltracking, with patella alta, trochlear dysplasia, and quadriceps tendinosis as significant predictors of maltracking (p < 0.001). Patellofemoral chondrosis was present in 63% (107/171), with maltracking contributing to higher grade chondrosis more so than increasing age (OR 8.4 versus 1.07). 13 mm was the optimal cut-off TT-TG distance to indicate maltracking (sensitivity 83%, specificity 80%). The prevalence of maltracking in the control group was 15% (p < 0.001 compared with the OSD group). CONCLUSION: Adults with sequelae of OSD are at high risk of maltracking and are likely to develop patellofemoral chondrosis. A lower threshold for identifying maltracking patients, including a lower cut-off TT-TG distance can help identify those at risk. Radiologists should maintain a high index of suspicion for maltracking in adults with OSD to guide clinical intervention.


Asunto(s)
Inestabilidad de la Articulación , Osteocondrosis , Articulación Patelofemoral , Adulto , Humanos , Imagen por Resonancia Magnética , Rótula , Articulación Patelofemoral/diagnóstico por imagen , Prevalencia , Estudios Retrospectivos , Tibia
12.
Acad Radiol ; 28(11): 1559-1569, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-32224035

RESUMEN

RATIONALE AND OBJECTIVES: To investigate differences in radiation dose and image quality for single-plane flat-panel-detector based interventional fluoroscopy systems from two vendors using phantom study and clinical procedures. MATERIALS AND METHODS: AlluraClarityIQ (Philips) and Artis Q (Siemens-Healthineers) interventional fluoroscopy systems were evaluated. Phantom study included comparison of system-reported air-kerma rates (AKR) for clinical protocols with simulated patient thicknesses (20-40 cm). Differences in system-reported radiation dose estimates, cumulative-air-kerma (CAK) and kerma-area-product (KAP), for different clinical procedures were investigated. Subset analysis investigated differences in CAK, KAP and other factors affecting radiation dose when the same patients underwent repeat embolization procedures performed by the same physician on the two different fluoroscopy systems. Two blinded interventional radiologists reviewed image-quality for these procedures using a five-point scale (1-5; 5-best) for five parameters. RESULTS: Phantom study revealed that air-kerma rates was significantly higher for Artis Q system for 30-40cm of simulated patient thicknesses (p < 0.05). Overall data analysis from 4381 clinical cases revealed significant differences in CAK and KAP for certain procedures (p < 0.05); with significantly lower values for AlluraClarityIQ systems (median CAK lower by: 29%-58%). Subset analysis with 40 patients undergoing repeat embolization procedures on both systems revealed that median CAK and KAP were significantly lower for AlluraClarityIQ systems (p < 0.02) by 45% and 31%, respectively. Image quality scores for AlluraClarityIQ systems were significantly greater (mean difference range for five parameters: 1.3-1.6; p < 0.005). CONCLUSION: Radiation dose and image quality differences were observed between AlluraClarityIQ and Artis Q systems. AlluraClarityIQ systems showed lower radiation utilization and an increase in subjective perception of image quality.


Asunto(s)
Embolización Terapéutica , Radiografía Intervencional , Fluoroscopía , Humanos , Fantasmas de Imagen , Dosis de Radiación
13.
Artículo en Inglés | MEDLINE | ID: mdl-32784134

RESUMEN

Thisstudy focuses on evaluating the real-time functionality of a customized interface and investigating the optimal parameters for intracardiac subharmonic-aided pressure estimation (SHAPE) utilizing Definity (Lantheus Medical Imaging Inc., North Billerica, MA, USA) and Sonazoid (GE Healthcare, Oslo, Norway) microbubbles. Pressure measurements within the chambers of the heart yield critical information for managing cardiovascular diseases. An alternative to current, invasive, clinical cardiac catheterization procedures is utilizing ultrasound contrast agents and SHAPE to noninvasively estimate intracardiac pressures. Therefore, this work developed a customized interface (on a SonixTablet, BK Ultrasound, Peabody, MA, USA) for real-time intracardiac SHAPE. In vitro, a Doppler flow phantom was utilized to mimic the dynamic pressure changes within the heart. Definity (15.0- [Formula: see text] microspheres corresponding to 0.1-0.15 mL) and Sonazoid (GE Healthcare; 0.4- [Formula: see text] microspheres corresponding to 0.05-0.15 mL) microbubbles were used. Data were acquired for varying transmit frequencies (2.5-4.0 MHz), and pulse shaping options (square wave and chirp down) to determine optimal transmit parameters. Simultaneously obtained radio frequency data and ambient pressure data were compared. For Definity, the chirp down pulse at 3.0 MHz yielded the highest correlation ( r = - 0.77 ± 0.2 ) between SHAPE and pressure catheter data. For Sonazoid, the square wave pulse at 2.5 MHz yielded the highest correlation ( r = - 0.72 ± 0.2 ). In conclusion, the real-time functionality of the customized interface has been verified, and the optimal parameters for utilizing Definity and Sonazoid for intracardiac SHAPE have been determined.


Asunto(s)
Medios de Contraste , Microburbujas , Fantasmas de Imagen , Ultrasonografía , Ultrasonografía Doppler
14.
Abdom Radiol (NY) ; 46(2): 562-569, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32743690

RESUMEN

PURPOSE: To assess the effect of gadobenate dimeglumine on magnetic resonance cholangiopancreatography (MRCP) and determine an appropriate time frame for performing MRCP sequences. MATERIALS AND METHODS: 2D MRCP sequences obtained after intravenous administration of gadobenate dimeglumine or gadobutrol over 14 months were reviewed retrospectively in randomized order by five abdominal radiologists, using a 3-point scale to rate biliary and pancreatic duct clarity (1 = no-, 2 = limited-, 3 = good visualization). Intraclass correlation coefficients were computed and mean scores were compared for both agents. For gadobenate dimeglumine exams, time delays between arterial phase and MRCP acquisition times were analyzed concerning duct clarity. For gadobutrol, only exams with delays ≥ 15 min were included. RESULTS: 134 exams (107 gadobenate dimeglumine, 27 gadobutrol) were included. Moderate reliability for pancreatic duct visualization and excellent reliability for visualization of intrahepatic bile ducts and upper and lower extrahepatic bile ducts were noted. No difference in mean scores was noted for pancreatic duct visualization (p = 0.66). Bile duct segment scores were lower with gadobenate dimeglumine (mean: 2.1-2.6) compared with gadobutrol (mean: 2.8-2.9) (p ≤ 0.006). For gadobenate dimeglumine, visualization scores varied depending on the delay between the arterial phase and MRCP acquisition (p ≤ 0.047). Good visualization for all bile duct segments was noted with delays of 7.2-9.4 min (95% confidence interval; mean 8.3 min). CONCLUSION: Bile duct clarity degraded on MRCP images with an increasing delay following gadobenate dimeglumine injection. 2D MRCP, thus, should be performed within 7.2 min after obtaining the arterial phase sequence to ensure good visualization of the entire biliary system.


Asunto(s)
Pancreatocolangiografía por Resonancia Magnética , Eliminación Hepatobiliar , Medios de Contraste , Humanos , Imagen por Resonancia Magnética , Meglumina/análogos & derivados , Compuestos Organometálicos , Reproducibilidad de los Resultados , Estudios Retrospectivos
15.
Am J Med Qual ; 35(5): 419-426, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32116008

RESUMEN

Diagnostic error and diagnostic delays in health care are widespread. This article outlines an improvement effort targeting weekday evening inpatient radiology delays through staffing changes replacing trainees with faculty-trainee team coverage, pushing faculty coverage from 4 pm to 8 pm. Order-report turnaround times (TATs), critical findings TATs for pneumothorax and intracranial hemorrhage (ICH), and percentage meeting target were compared pre and post implementation for the 4 to 8 pm time frame using the Mann-Whitney U and χ2 tests, respectively. Stakeholder surveys assessed patient safety, morale, education, and operational efficiency. Median TATs (minutes) improved: X-rays 906 to 112, computed tomography 994 to 84, magnetic resonance imaging 1172 to 233, and ultrasound 88 to 58. Median critical findings TATs (minutes) improved from 853 to 30 and 112 to 22 for pneumothorax and ICH, respectively, and the percentage meeting target improved from 45% to 65%. Survey results reported perceived improvement in patient safety, education, and operational efficiency and no impact on morale.


Asunto(s)
Atención Posterior/organización & administración , Mejoramiento de la Calidad/organización & administración , Servicio de Radiología en Hospital/organización & administración , Atención Posterior/normas , Humanos , Hemorragias Intracraneales/diagnóstico por imagen , Neumotórax/diagnóstico por imagen , Indicadores de Calidad de la Atención de Salud , Servicio de Radiología en Hospital/normas , Factores de Tiempo , Tiempo de Tratamiento , Flujo de Trabajo
16.
Med Phys ; 46(7): e671-e677, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31055845

RESUMEN

PURPOSE: We summarize the AAPM TG248 Task Group report on interoperability assessment for the commissioning of medical imaging acquisition systems in order to bring needed attention to the value and role of quality assurance testing throughout the imaging chain. METHODS: To guide the clinical physicist involved in commissioning of imaging systems, we describe a framework and tools for incorporating interoperability assessment into imaging equipment commissioning. RESULTS: While equipment commissioning may coincide with equipment acceptance testing, its scope may extend beyond validation of product or purchase specifications. Equipment commissioning is meant to provide assurance that a system is ready for clinical use, and system interoperability plays an essential role in the clinical use of an imaging system. CONCLUSION: The functionality of a diagnostic imaging system extends beyond the acquisition console and depends on interoperability with a host of other systems such as the Radiology Information System, a Picture Archive and Communication System, post-processing software, treatment planning software, and clinical viewers.


Asunto(s)
Diagnóstico por Imagen , Procesamiento de Imagen Asistido por Computador , Informe de Investigación , Sociedades Médicas , Humanos , Control de Calidad
17.
Med Phys ; 45(11): e1146-e1160, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30255505

RESUMEN

Beginning with the advent of digital radiography systems in 1981, manufacturers of these systems provided indicators of detector exposure. These indicators were manufacturer-specific, and users in facilities with equipment from multiple manufacturers found it a challenge to monitor and manage variations in indicated exposure in routine clinical use. In 2008, a common definition of exposure index (EI) was realized in International Electrotechnical Commission (IEC) International Standard 62494-1 Ed. 1, which also introduced and defined the deviation index (DI), a number quantifying the difference between the detector EI for a given radiograph and the target exposure index (EIT ). An exposure index that differed by a constant from that established by the IEC and the concept of the deviation index also appear in American Association of Physicists in Medicine (AAPM) Report No. 116 published in 2009. The AAPM Report No. 116 went beyond the IEC standard in supplying a table (Table II in the report of TG-116) titled "Exposure Indicator DI Control Limits for Clinical Images," which listed suggested DI ranges and actions to be considered for each range. As the IEC EI was implemented and clinical DI data were gathered, concerns were voiced that the DI control limits published in the report of TG-116 were too strict and did not accurately reflect clinical practice. The charge of task group 232 (TG-232) and the objective of this final report was to investigate the current state of the practice for CR/DR Exposure and Deviation Indices based on AAPM TG 116 and IEC-62494, for the purpose of establishing achievable goals (reference levels) and action levels in digital radiography. Data corresponding to EI and DI were collected from a range of practice settings for a number of body parts and views (adults and pediatric radiographs) and analyzed in aggregate and separately. A subset of radiographs was also evaluated by radiologists based on criteria adapted from the European Guidelines on Quality Criteria for Diagnostic Radiographic Images from the European Commission. Analysis revealed that typical DI distribution was characterized by a standard deviation (SD) of 1.3-3.6 with mean DI values substantially different from 0.0, and less than 50% of DI values fell within the significant action limits proposed by AAPM TG-116 (-1.0 ≤ DI ≤ 1.0). Recommendations stemming from this analysis include targeting a mean DI value of 0.0 and action limits at ±1 and ±2 SD of the DI based on actual DI data of an individual site. EIT values, DI values, and associated action limits should be reviewed on an ongoing basis and optimization of DI values should be a process of continuous quality improvement with a goal of reducing practice variation.


Asunto(s)
Exposición a la Radiación/análisis , Intensificación de Imagen Radiográfica/instrumentación , Sociedades Científicas , Intensificación de Imagen Radiográfica/normas , Estándares de Referencia
18.
Ultrasonics ; 84: 329-340, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29223692

RESUMEN

About 92.1 million Americans suffer from at least one type of cardiovascular disease. Worldwide, cardiovascular diseases are the number one cause of death (about 31% of all global deaths). Recent technological advancements in cardiac ultrasound imaging are expected to aid in the clinical diagnosis of many cardiovascular diseases. This article provides an overview of such recent technological advancements, specifically focusing on tissue Doppler imaging, strain imaging, contrast echocardiography, 3D echocardiography, point-of-care echocardiography, 3D volumetric flow assessments, and elastography. With these advancements ultrasound imaging is rapidly changing the domain of cardiac imaging. The advantages offered by ultrasound imaging include real-time imaging, imaging at patient bed-side, cost-effectiveness and ionizing-radiation-free imaging. Along with these advantages, the steps taken towards standardization of ultrasound based quantitative markers, reviewed here, will play a major role in addressing the healthcare burden associated with cardiovascular diseases.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico por imagen , Ecocardiografía/tendencias , Medios de Contraste , Circulación Coronaria , Diagnóstico por Imagen de Elasticidad/tendencias , Humanos , Sistemas de Atención de Punto
19.
Ultrasound Med Biol ; 43(11): 2718-2724, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28807449

RESUMEN

This study evaluated the feasibility of employing non-invasive intra-cardiac pressure estimation using subharmonic signals from ultrasound contrast agents in humans. This institutional review board-approved proof-of-concept study included 15 consenting patients scheduled for left and right heart catheterization. During the catheterization procedure, Definity was infused intra-venously at 4-10 mL/min. Ultrasound scanning was performed with a Sonix RP using pulse inversion, three incident acoustic output levels and 2.5-MHz transmit frequency. Radiofrequency data were processed and subharmonic amplitudes were compared with the pressure catheter data. The correlation coefficient between subharmonic signals and pressure catheter data ranged from -0.3 to -0.9. For acquisitions with optimum acoustic output, pressure errors between the subharmonic technique and catheter were as low as 2.6 mmHg. However, automatically determining optimum acoustic output during scanning for each patient remains to be addressed before clinical applicability can be decided.


Asunto(s)
Cateterismo Cardíaco , Medios de Contraste , Aumento de la Imagen/métodos , Procesamiento de Señales Asistido por Computador , Ultrasonografía/métodos , Función Ventricular/fisiología , Acústica , Anciano , Anciano de 80 o más Años , Determinación de la Presión Sanguínea , Femenino , Fluorocarburos , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Microburbujas , Persona de Mediana Edad
20.
Ultrasound Med Biol ; 43(7): 1401-1410, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28433436

RESUMEN

Interstitial fluid pressure (IFP) in rats with breast cancer xenografts was non-invasively estimated using subharmonic-aided pressure estimation (SHAPE) versus an invasive pressure monitor. Moreover, monitoring of IFP changes after chemotherapy was assessed. Eighty-nine rats (calibration n = 25, treatment n = 64) were injected with 5 × 106 breast cancer cells (MDA-MB-231). Radiofrequency signals were acquired (39 rats successfully imaged) with a Sonix RP scanner (BK Ultrasound, Richmond, BC, Canada) using a linear array (L9-4, transmit/receive: 8/4 MHz) after administration of Definity (Lantheus Medical Imaging, North Billerica, MA, USA; 180 µL/kg) and compared with readings from an invasive pressure monitor (Stryker, Berkshire, UK). An inverse linear relationship was established between tumor IFP and SHAPE (y = -1.06x + 28.27, r = -0.69, p = 0.01) in the calibration group. Use of this relationship in the treatment group resulted in r = 0.74 (p < 0.05) between measured (pressure monitor) and SHAPE-estimated IFP (average error: 6.24 mmHg). No significant before/after differences were observed with respect to paclitaxel treatment (5 mg/kg, Mayne Pharma, Paramus, NJ, USA) with either method (p ≥ 0.15).


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/tratamiento farmacológico , Monitoreo de Drogas/métodos , Líquido Extracelular/diagnóstico por imagen , Manometría , Paclitaxel/administración & dosificación , Ultrasonografía , Animales , Antineoplásicos Fitogénicos/administración & dosificación , Neoplasias de la Mama/fisiopatología , Calibración , Línea Celular Tumoral , Monitoreo de Drogas/normas , Líquido Extracelular/fisiología , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Manometría/instrumentación , Presión , Ratas , Ratas Desnudas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento , Ultrasonografía/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...